Common UPS Faults and Solutions: Inverter Issues, Over Temperature, and More

Uninterruptible Power Supplies (UPS) are critical for protecting sensitive equipment from power interruptions. When a UPS fails or shows faults, it can disrupt operations and cause stress. Understanding common UPS faults and how to address them can save time and prevent damage. This post covers typical UPS problems such as inverter faults, over temperature, DC bus faults, internal faults, display issues, and more. You will also find practical tips to troubleshoot these faults and know when to call for professional help.


Close-up view of UPS control panel showing fault indicators and display screen
UPS control panel with fault indicators

Inverter Faults and What They Mean


The inverter is the heart of a UPS, converting DC battery power to AC output. An inverter fault usually means the UPS cannot supply clean power to connected devices. Common causes include:


  • Component failure such as damaged transistors or capacitors

  • Overload conditions where the UPS is asked to supply more power than its rating

  • Short circuits in the output wiring or connected equipment


When an inverter fault occurs, the UPS may shut down or switch to bypass mode. To troubleshoot:


  • Check for visible damage or burnt smells inside the UPS

  • Verify the load does not exceed the UPS capacity

  • Inspect output wiring for shorts or loose connections

  • Reset the UPS and monitor if the fault recurs


If the inverter fault persists, professional service is needed to replace faulty components safely.


Over Temperature Faults and Cooling Tips


UPS units generate heat during operation, especially under heavy load. Over temperature faults happen when internal sensors detect temperatures beyond safe limits. This can cause the UPS to shut down to protect itself.


Common reasons for overheating:


  • Blocked ventilation or dust buildup inside the UPS

  • Operating the UPS in a hot environment without adequate cooling

  • Faulty cooling fans or sensors


To prevent overheating:


  • Keep the UPS in a well-ventilated area away from heat sources

  • Clean dust filters and vents regularly

  • Check that cooling fans are running properly

  • Avoid overloading the UPS beyond its rated capacity


If the UPS continues to overheat despite these steps, contact a technician to inspect internal cooling systems.


DC Bus Faults Explained


The DC bus is the internal circuit that links the battery to the inverter. A DC bus fault indicates a problem with this connection, often caused by:


  • Battery issues such as low voltage or bad cells

  • Faulty capacitors or wiring in the DC bus circuit

  • Internal component failure


Symptoms include the UPS failing to switch to battery power during outages or showing error codes related to DC bus voltage.


To address DC bus faults:


  • Test battery voltage and replace weak or damaged batteries

  • Inspect internal wiring for damage or corrosion

  • Reset the UPS and observe if the fault clears


Persistent DC bus faults require professional diagnosis and repair.


Internal Faults and Their Impact


Internal faults cover a range of issues inside the UPS, including circuit board failures, sensor errors, or firmware glitches. These faults often trigger alarms or error messages on the display.


Common internal faults include:


  • Communication errors between modules

  • Sensor malfunctions reporting incorrect data

  • Firmware corruption causing erratic behavior


When an internal fault occurs:


  • Power cycle the UPS to see if the fault resets

  • Check for firmware updates from the manufacturer

  • Review the user manual for specific error codes


If internal faults continue, avoid using the UPS until a qualified technician inspects it.


UPS Won’t Turn On but Power Is Present


Sometimes a UPS appears dead even though it is plugged in and power is available. Possible causes:


  • Blown internal fuses or circuit breakers

  • Battery completely drained or disconnected

  • Faulty power switch or control board


Troubleshooting steps:


  • Check external circuit breakers and fuses

  • Inspect battery connections and charge status

  • Try a hard reset or disconnect and reconnect the battery


If the UPS still won’t power on, professional service is necessary to diagnose internal faults.


Display and Navigation Faults


The UPS display provides vital information about status and faults. When the display or navigation buttons fail:


  • The screen may be blank or show garbled characters

  • Buttons may not respond or cycle through menus incorrectly


Causes include:


  • Loose or damaged display cables

  • Firmware bugs affecting the user interface

  • Faulty control board or display module


Try rebooting the UPS and updating firmware if available. If the problem persists, the display or control board may need replacement.


UPS Goes Online Briefly Then Output Breaker Trips


A UPS that powers on but then quickly trips the output breaker usually faces:


  • Output short circuits or overloads

  • Faulty output breaker or wiring

  • Internal inverter or power stage faults


Steps to resolve:


  • Disconnect all loads and test the UPS with no load

  • Inspect output wiring and connected equipment for shorts

  • Reset the output breaker and monitor behavior


If the breaker trips repeatedly without load, the UPS requires professional repair.


Firmware and Alarm Acknowledgement


Firmware controls UPS operations and can affect fault detection and alarms. Keeping firmware updated can fix bugs and improve stability.


  • Check the manufacturer’s website for firmware updates

  • Follow instructions carefully to avoid corrupting the UPS


Alarm acknowledgement allows you to silence warnings temporarily while investigating faults. Always address the root cause rather than ignoring alarms.


Tips and Tricks for UPS Fault Management


  • Regularly inspect and clean your UPS to prevent dust and heat buildup

  • Test batteries every 6 months and replace them every 3-5 years

  • Avoid overloading the UPS beyond its rated capacity

  • Keep firmware updated to benefit from fixes and improvements

  • Document fault codes and symptoms for faster troubleshooting

  • Use the UPS manual and manufacturer support resources


When to Call for Professional Help


If your UPS faults do not clear after basic troubleshooting, or if you encounter complex issues such as:

  • Inverter faults

  • DC bus faults

  • Persistent internal errors

It is advisable to:

  1. Switch on the maintenance bypass.

  2. Contact a qualified technician.

Attempting repairs without proper knowledge can be dangerous and may void warranties.


We offer expert UPS diagnostics and repairs day or night. Book a callout to get your UPS back to reliable operation quickly and safely.



 
 
 